How to Protect Your Blomberg Dryer Control Board
Need a technician in Burnaby, Surrey or New Westminster?
Call Doctor Appliance at 604-729-0499. $85 service call, included in labour if the repair goes ahead. We serve Metro Vancouver: Burnaby, Surrey, New Westminster, Coquitlam, Port Coquitlam, Vancouver, Richmond, Delta and Langley.
Call 604-729-0499 Book a Repair
The main control board is the most expensive common repair on a Blomberg heat pump dryer, and it is the repair we do most often on these machines. In our experience other kinds of board faults are rare: the board simply burns out. You cannot make a circuit board last forever, but you can remove most of the things that stress it. This guide covers what actually helps, what does not, and how to tell when the board has already failed.
What the control board does
The main control board is the brain of the dryer. It reads the program knob and buttons, runs the drum motor, the fan and the heat pump compressor, reads the moisture and temperature sensors, controls the condensate pump and lights up every symbol on the display. When it fails, the whole dryer usually goes dead at once.
How a failed board usually shows up
The pattern we see most on Blomberg dryers is simple:
- No lights at all on the display, even though the dryer is plugged in and the breaker is on.
- A ticking or clicking sound from inside the dryer, often from the area of the control panel.
No lights plus ticking almost always means the main control board. Before you call, rule out the simple things described in our article on a Blomberg dryer that won’t turn on.
1. Give the dryer a correct, dedicated power supply
Your Blomberg heat pump dryer runs on 208–240 V and must be plugged into a properly grounded outlet on its own circuit with a suitable breaker. Blomberg is clear about several things in the owner’s guide:
- Do not use extension cords, multi-plugs or adapters.
- Do not modify the plug. If it does not fit, have a qualified electrician install the correct outlet.
- If you are not sure the outlet is properly grounded, have it checked by an electrician.
A loose, worn or badly wired outlet makes the voltage at the dryer unstable, and unstable power is hard on electronics. If the plug feels warm, looks discoloured or fits loosely, have the outlet replaced.
2. Reduce power surges
Power cuts, storms and switching surges on the grid are a fact of life in Metro Vancouver, especially in winter. The dryer’s board has no special protection against a large surge.
- Ask a licensed electrician about a whole-home surge protector installed at your electrical panel. It protects every appliance in the home, including the dryer, without adding an extension cord or power bar (which Blomberg does not allow).
- During a power cut, switch the dryer off with its On/Off button, or turn off its breaker. Turn it back on only after the power has been stable for a few minutes. The moment power comes back is when surges are most likely.
3. Switch it off when you are not using it
Blomberg recommends turning the dryer off with the On/Off button when it is not in use, and unplugging it when it will not be used. Leaving the electronics energized around the clock means more hours under voltage and more exposure to whatever happens on the line. Make it a habit: take the laundry out, switch the dryer off.
4. Keep it cool and ventilated
Electronics fail faster when they run hot. The heat pump also gives off warmth into the room.
- Blomberg specifies operation between +5°C and +35°C. Do not install the dryer in an unheated garage or a hot, closed laundry closet.
- Keep the ventilation grids at the front of the machine clear. Do not push laundry baskets or bags against them.
- In a closet, follow Blomberg’s clearances and ventilation openings: the closet door needs two openings, one near the bottom and one near the top.
- Ventilate the room during drying. In a small room with the door closed, the temperature can climb a lot.
5. Keep the filters clean
Clogged filters do not damage the board directly, but they make every cycle longer. Longer cycles mean more running hours for the compressor, fans and electronics, and more heat inside the machine. Clean the lint filter after every load and the filter drawer when the warning light comes on. Our step-by-step guide shows how to clean the filters properly.
6. Keep water away from the electronics
- Never wash or spray the dryer with water. Blomberg warns about the risk of electric shock.
- If the dryer drains through a hose, make sure the hose is secured. A hose that comes loose can flood the floor under the dryer.
- If the dryer sits on a washer, use the correct stacking kit. A washer that leaks or walks during spin can soak or shake the dryer above it.
7. Don’t try to repair the board yourself
The board carries mains voltage. Blomberg’s owner’s guide states that the dryer should not be repaired by the user, and a board that has been tampered with is often impossible to repair afterwards. If the dryer is dead, unplug it and call a technician.
What does not help
- Pressing buttons repeatedly or turning the knob back and forth on a dead dryer. It will not reset a burned-out board.
- Plugging the dryer into a power bar “for protection”. Blomberg does not allow multi-plugs, and a power bar rated for small electronics is not designed for a 240 V dryer.
- Unplugging and plugging back in over and over. If it does not come back after one reset at the breaker, it needs diagnosis.
Already failed? Repair or replace the board
When the board does burn out, the dryer is usually still worth repairing: the drum, motor and heat pump are fine. Our article on the Blomberg dryer control board explains the symptoms, repair options and cost, and our Blomberg dryer repair page covers the full service. Prices are on our price list.
Save $25 on a Blomberg control board replacement: see the offer and terms on our coupons page.
FAQ
The most common sign we see is no lights at all on the display combined with a ticking or clicking sound from inside the machine, while the outlet and breaker are fine.
No. Blomberg does not allow extension cords or multi-plugs on the dryer. A whole-home surge protector installed at the electrical panel by a licensed electrician is the right way to add surge protection.
Yes. Blomberg recommends switching the dryer off with the On/Off button when it is not in use. It reduces the time the electronics spend under power.
In most cases, yes. The board is one part; the drum, motor and heat pump system are usually in good condition. A technician can confirm on site.
We don’t recommend it. The board works with mains voltage, and Blomberg’s manual says the dryer should not be repaired by the user. A wrong diagnosis also means paying for a board you didn’t need.
Need a technician in Burnaby, Surrey or New Westminster?
Call Doctor Appliance at 604-729-0499. $85 service call, included in labour if the repair goes ahead. We serve Metro Vancouver: Burnaby, Surrey, New Westminster, Coquitlam, Port Coquitlam, Vancouver, Richmond, Delta and Langley.